Technical Data:
- Linearity < ± 0.5 hPa
- Temperature range -35...70 °C
- Temperature error max. ± 0.5 hPa (-20...+50 °C)
- Temperature hysteresis < 0.2 hPa
- Settling time < 10 s
- Operating current max. 20 mA
- Integrated over voltage protection
- Two-wire technology